检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《净水技术》2010年第2期29-31,共3页Water Purification Technology
摘 要:垃圾渗滤液生化处理后的尾水COD_(Cr)浓度约为400~800 mg/L,因其可生化性较差,所以通过传统办法很难进一步降低出水COD_(Cr)浓度,为使其能直接排放自然水体,本课题采用"铁碳微电解-Fenton氧化-混凝沉淀"组合工艺处理垃圾渗滤液生化处理后的尾水,处理后的垃圾渗滤液尾水COD去除率可达71.4%,接近国家污水综合排放一级排放标准。The CODCr is about 400-800 mg/L of the landfill leachate tailwater which is already treated by biological processes. As the low hiodegrability, it's very difficult to further deduce the CODCr by traditional ways. In order to meet the standard of discharging to nature water, the tailwater is advanced treated by ironcarbon micro-electrolysis, Fenton oxidation and coagulation-sedimentation. The removal of CODCr is up to 71.4 %, and the CODc~ value of effluent is close to class one of "Integrated Water Discharge Standard" (GB 8978--1996).
关 键 词:垃圾渗滤液 深度处理 铁碳微电解 FENTON氧化 混凝沉淀