检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:赵泉[1] 岳大磊[1] 钟志光[1] 唐志锟[1] 梁桂兰[1] 萧达辉[1] 张少萍[1] 朱彬
机构地区:[1]广东出入境检验检疫局,广州510623 [2]莱伯泰科有限公司广州办事处,广州510260
出 处:《理化检验(化学分册)》2010年第4期379-380,共2页Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
基 金:国家质量监督检验检疫总局科研计划项目(2005B065.2)
摘 要:样品经微波消解及在线稀释进样,采用火焰原子吸收光谱法测定锂电池中锂的含量。在优化的试验条件下,锂的线性范围为0.01~2.5 mg·L^(-1)。该法用于测定锂电池中锂的含量,回收率在94.0%~104.0%之间,相对标准偏差(n=7)在1.6%~4.5%之间。The sample of lithium cell was treated with microwave digestion system and the sample solution was introduced by on-line dilution system.The content of lithium was determined by AAS.Under the optimized conditions,linearity range of lithium was kept from 0.01 mg·L^-1 to 2.5 mg·L^-1.The proposed method was applied to the determination of lithium in lithium cell,giving values of recovery in the range of 94.0%-104.0%and RSD(n=7) in the range of 1.6%-4.5%.