检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:熊仁海[1] 莫伟明[1] 雷娜[1] 王兵[1] 陆佳昕[1]
机构地区:[1]黄石市第二医院肝胆外科,黄石市腹腔镜治疗中心,湖北黄石435002
出 处:《中国普外基础与临床杂志》2010年第4期376-378,共3页Chinese Journal of Bases and Clinics In General Surgery
摘 要:目的探讨腹腔镜腹部手术中钛夹内固定腹腔引流管的疗效。方法回顾性分析我院1997~2009年期间210例腹腔镜腹部手术中应用钛夹固定腹腔引流管的临床资料。结果210例引流管放置5~20d,平均8.5d,无引流管漂移、挪位和引流不畅发生,且拔管顺利,未出现腹腔积液、腹腔脓肿、腹膜炎等并发症。结论腹腔镜腹部手术中,用钛夹内固定腹腔引流管的放置方法简单,引流效果可靠,疗效安全肯定,可明显减少手术并发症,值得临床推广使用。Objective To investigate the curative effect of peritoneal drainage tube fixation with titanium clamp in 210 patients during laparoscopic operations.Methods The clinical data of 210 patients with peritoneal drainage fixation via titanium clamp during laparoscopic operations in this hospital were analyzed retrospectively.Results In 210 patients,drainage tube placement lasted for 5-20 d with an average of 8.5 d.No complications such as drainage tube drifting,position changing or obstructed drainage occurred,and all the patients were successfully extubated.Conclusion During laparoscopic operations,the method that drainage tube fixed with titanium clamp is simple with reliable drainage results,affirmed curative efficacy and obviously decreased operative complications,which is worthy of clinical practice and generalization.