IT300负荷开关故障分析及建议  

Fault analysis and suggestions for IT300 load switch

在线阅读下载全文

作  者:霍凤鸣[1] 李英楠 李晓峰[1] 庞先海[1] 

机构地区:[1]河北省电力研究院,河北石家庄050021 [2]国网国际发展有限公司,北京100120

出  处:《中国电力》2010年第5期69-71,共3页Electric Power

摘  要:IT300负荷开关属于中压开关设备,适用于短路电流较大的发电工程。该型负荷开关设计先进,动、热稳定电流较大,结构简单。由于该产品实际运行量较少,在交付用户使用中尚存在一些问题,有些问题较为严重。通过IT300负荷开关发生的一起爆炸故障,对该型设备结构、动作原理、故障原因进行了分析,通过分析对该型设备的交接、运行、维护提出一些注意事项及建议。IT300 load switch is medium vohage switchgear produced by France SDCEM for power plant project with bigger short-circuit current,which has advanced design, large thermal short-time withstand current, and simple structure. However, there are some problems in use due to the less actual usage of this product, some more serious. The equipment structure and movement principles of IT300 and the fault causes of an explosion of IT300 were analyzed, and some considerations and suggestions were also presented in the device hand-over, operation and maintenance.

关 键 词:IT300 负荷开关 应用 事故分析 

分 类 号:TM564.2[电气工程—电器]

 