作 者:雷敏[1] 李绍晔 杨春平[1] 刘丽清 谢更新[1]
机构地区:[1]湖南大学环境科学与工程学院环境生物与控制教育部重点实验室,长沙市岳麓山8号410082 [2]湖南中烟工业有限责任公司长沙技术中心,长沙市劳动东路346号410014
出 处:《烟草科技》2010年第4期44-47,64,共5页Tobacco Science & Technology
基 金:湖南中烟工业有限责任公司科技计划项目(2008160801)资助
摘 要:为了采用微波消解和氢化-原子荧光光谱法(HG-AFS)法准确测定卷烟接装纸中As含量,研究了消解体系、消解程序和赶酸程度,以及微波仪的类型等对接装纸中As测定量的影响。结果表明:①在微波条件下,HNO3∶HF∶HCl∶H2O2体积比=6∶0.2∶1∶1的体系可将接装纸样品消解完全;②As的检出限为1.38 ng/L,回收率98%~110%,RSD为6%~10%;③Berghof和CEM两种消解仪的消解效果基本一致。In order to accurately determine As in tipping paper samples by HG-AFS with microwave digestion,the effects of digestion system,digestion procedure,acid removal and type of microwave instrument on As determination were investigated.The results showed that: 1) tipping paper samples were completely digested in HNO3∶HF∶HCl∶H2O2=6∶0.2∶1∶1(v/v) system in a microwave field;2) the recoveries of As was from 98% to 110% with RSD of 6% to 10% and detection limit of 1.38 ng/L;3) the performance of microwave instrument Berghof was virtually the same as that of CEM.
分 类 号:TS761.2[轻工技术与工程—制浆造纸工程] TS411[农业科学—烟草工业]