Bond-slip constitutive relationship between bars and mortar for block masonry  被引量:1

Bond-slip constitutive relationship between bars and mortar for block masonry

在线阅读下载全文

作  者:郑怡 李莉 刘明 许嘉龙 张延年 

机构地区:[1]School of Civil Engineering,Shenyang Jianzhu University [2]Liaoning Building Materials Inspection Institute [3]School of Materials Science and Engineering,Wuhan University of Technology

出  处:《Journal of Harbin Institute of Technology(New Series)》2010年第2期176-179,共4页哈尔滨工业大学学报(英文版)

基  金:Sponsored by the National Science and Technology Pillar Program during the 11th Five-Year Plan Period of China(Grant No. 2009BAK58B03-03 and 2006BAJ03A01-05);the Key Laboratory of Structural Engineering of Shenyang Jianzhu University,China(Grant No. JG200705);the Science & Re-search Program of Shenyang,China(Grant No. 1091064-A-00)

摘  要:Ten specimens were tested in this paper in order to study the bond behavior and the process of force transfer when bars adhered to mortar. The development of the bond stress between bars and mortar was calculated. Test results show that the maximum bond-stress is not influenced by the bar bond length and increases as the increased splitting strength of mortar for block. The local bond stress-slip curve was obtained. Then,based on the regressive analysis of test data,two bond shearing stress-slip constitutive models between bars and mortar were proposed. The models can be used in the numerical simulation or finite element analysis and provide references for the improvement of the corresponding design codes.Ten specimens were tested in this paper in order to study the bond behavior and the process of force transfer when bars adhered to mortar. The development of the bond stress between bars and mortar was calculated. Test results show that the maximum bond-stress is not influenced by the bar bond length and increases as the increased splitting strength of mortar for block. The local bond stress-slip curve was obtained. Then, based on the regressive analysis of test data, two bond shearing stress-slip constitutive models between bars and mortar were proposed. The models can be used in the numerical simulation or finite element analysis and provide references for the improvement of the corresponding design codes.

关 键 词:reinforced masonry MORTAR BOND-SLIP constitutive model 

分 类 号:TU365[建筑科学—结构工程]

 