作 者:康建中[1] 刘晓瑷[1] 肖志琴[1] 黄咏梅[1] 吴愉[1] 程利南[1]
机构地区:[1]中国福利会国际和平妇幼保健院上海市计划生育技术指导所,上海200030
出 处:《生殖与避孕》2010年第4期258-262,共5页Reproduction and Contraception
摘 要:目的:探讨宫腔镜下取出宫内节育器(IUD)手术的死亡原因,寻找提高宫腔镜下取器安全性的措施。方法:回顾性调查上海市87所医院2001.01.01~2007.12.31期间所有宫腔镜下IUD取出术11110例,其中意外死亡4例。结果:4个病例的死亡原因均为肺栓塞(空气栓塞)。与死亡相关的主要因素有:手术前准备不充分;2次手术时间间隔太短;手术操作不规范;术中观察不仔细;抢救不及时等。结论:建立与宫腔镜下手术配套的抢救设备、操作规范和提高医务人员临床经验资质是非常必要的。Objective: To analyze the possible causes leading to death from the hysteroscopic-guided intrauterine device (IUD) retrieval with a purpose to provide preventive measures to improve the safety. Methods: All cases (11 110) of IUD removal under hysteroscopy performed at 87 hospitals in Shanghai from 2001 to 2007 were reviewed. Four dead cases were reported. Results: Air embolism was suspected as the cause of death. Associated risk factors included insufficient preoperative preparation, short duration between surgeries, non-standard procedure, careless observation and untimely resuscitation. Conclusion: These case reports emphasize the necessity of establishing the standard guideline for hysteroscope-guided IUD removal, which includes early interventions taken such as prevention, early detection and management of the fatal complications and improving the qualification of operator.