三维电极氧化降解苯酚废水的试验研究  被引量:15

Experimental study on the oxidation degradation of phenol wastewater by three-dimensional electrode

在线阅读下载全文

作  者:夏怡[1,2] 李亚峰[1] 程琳[1] 

机构地区:[1]沈阳建筑大学市政与环境工程学院,辽宁沈阳110168 [2]辽宁地质工程职业学院,辽宁丹东118008

出  处:《工业水处理》2010年第5期27-29,48,共4页Industrial Water Treatment

基  金:辽宁省教育厅青年基金项目(2005344);沈阳建筑大学省级重点实验室开放基金资助项目(HJ200703)

摘  要:采用自制反应器氧化降解苯酚废水,通过试验分析反应时间、pH、电解电压、Fe2+投加量对三维电极氧化降解苯酚废水中苯酚去除效果的影响,并确定最佳反应条件。试验结果表明,三维电极氧化降解苯酚废水有较好的去除效果,在最佳反应条件下,即反应时间为90 min,pH=3,电解电压15 V,Fe2+投加浓度为1 mmol/L,对苯酚质量浓度为300 mg/L的模拟废水的最大苯酚去除率达到91.2%。A self-made reactor has been used for the oxidation degradation of phenol wastewater. Through experimen- tation, the effects of its reaction time, pH, electrolyte voltage and dosage of Fe^2+ on the phenol removal efficiency from phenol wastewater by three-dimensional electrode oxidation degradation are analyzed. The optimum reaction conditions are determined. The results show that it has a better removal effect. The highest removal rate of simulated phenol wastewater (mass concentration is 300 mg/L) reaches 91.2%, when the optimum conditions are as follows: reaction time is 90 min, pH is 3, electrolyte voltage is 15 V,concentration of Fe^2+ is 1 mmol/L.

关 键 词:三维电极 FENTON试剂 苯酚废水 电化学 

分 类 号:X703.1[环境科学与工程—环境工程]

 