作 者:肖志勤[1]
出 处:《腹腔镜外科杂志》2010年第5期394-396,共3页Journal of Laparoscopic Surgery
摘 要:目的:探讨关节镜治疗胫骨平台骨折的应用价值及方法。方法:回顾分析2003年6月至2009年6月用关节镜治疗胫骨平台骨折34例患者的临床资料。结果:34例经6个月~6年随访,骨折复位良好,无感染和严重骨关节炎发生,Hohl评分:优27例,良4例,中3例,优良率91.2%。结论:SchatzkerⅠ~Ⅳ型胫骨平台骨折于关节镜监视下复位,固定可靠,可避免遗留关节内的伴随损伤,具有患者创伤小,康复快,并发症少等优势。Objective:To investigate the application value and method of arthroscopic treatment of tibial plateau fractures.Methods:The clinical data of 34 patients with tibial plateau fracture underwent arthroscopic treatment were retrospectively analyzed between Jun.2003 and Jun.2009.Results:After 6 months to six years follow-up of the 34 patients,it was found that fracture reduction was satisfied,no infection and severe osteoarthritis occurred.According to Hohl score,there were 27 cases of excellence,4 cases in good and 3 cases in middle rank,excellence and good rate was 91.2%.Conclusions:Arthroscopic reduction and fixation of Schatzker Ⅰ-Ⅳ tibial plateau fracture is reliable,can avoid remaining intra-articular incidental injury,and has advantages of less trauma,faster recovery and less complications.