个体采样器旋风式粉尘采样头的设计验证  被引量:1

Design Verification Test on Cyclone Sampling Head of Personal Sampling Pump

在线阅读下载全文

作  者:孟超[1] 赵敬 刘璐[1] 

机构地区:[1]首都经济贸易大学安全与环境工程学院,北京市100070 [2]浙江省安全生产技术检测检验中心

出  处:《职业与健康》2010年第10期1110-1113,共4页Occupation and Health

基  金:北京市教育委员会科技面上项目:PC-TWA采样器研制(EM200710038002)

摘  要:目的通过实验验证使用Barth理论设计的旋风式粉尘采样头能否符合英国医学研究委员会制定的标准曲线(BM-RC曲线)的要求。方法对使用Barth理论设计的旋风式粉尘采样头进行实验室检测以及与进口旋风式粉尘采样头进行比对。结果Barth理论设计的旋风式粉尘采样头与BMRC曲线对应值偏差的实验室检测值为4.9%,进口旋风式粉尘采样头与BMRC曲线对应值偏差2.3%。结论Barth法设计的旋风式粉尘采样头与进口旋风式粉尘采样头采样性能的差别较小,能够满足BMRC曲线的要求。[Objective]To verify the cyclone sampling head which designed by the Barth's theory in line with the BMRC curve through experimental test.[Methods]Experimental test was performed on cyclone sampling head which was designed by Barth's theory,the results were compared with import cyclone sampling head.[Results]The cyclone sampling head designed by Barth's theory with the BMRC curve deviation’s the laboratory examination value was 4.9%,the deviation of the import sampling head was 2.3%.[Conclusion]The difference of sampling efficiency is not significant between the Barth's theory designed sampling head and the import sampling head,so that the Barth's theory designed sampling head can meet the requirement of the BMRC curve.

关 键 词:旋风式采样头 采样效能 BMRC曲线 

分 类 号:R135.2[医药卫生—劳动卫生]

 