检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杜宁[1,2] 王玉[1,2] 蔡美明[2] 狄斌[1]
机构地区:[1]中国药科大学药物分析教研室,南京210009 [2]江苏省食品药品检验所
出 处:《中国药师》2010年第6期828-829,共2页China Pharmacist
摘 要:目的:采用光纤化学传感技术,实时、在位监测米非司酮片的溶出度。方法:运用E_(1cm)^(1%)值法监测米非司酮片的溶出全过程。结果:本法监测的溶出过程曲线与《中国药典》2005年版方法手动取样测定所拟合的曲线基本一致。结论:光纤药物溶出度监测仪可以准确测定固体药物的体外溶出度,真实地反映药物溶出的全过程。Objective: To establish a processing analysis method of the dissolution test of mifepristone tablets-fiber optic chemical sensor dissolution test (FOCSDT). Method: The real time process of mifepristone tablets was determined with the dissolution test system,and the E1%1cm method was used in data processing. Result: This procession analysis could test the whole process of the drug and get dissolution graph. The parameters obtained by FOCSDT had no significant difference compared with the method in ChP2005. Result: This method can reflect the real dissolution process and obtain the total information.
关 键 词:光纤药物溶出度监测仪 溶出度 米非司酮片