Electrochemical Study of Lincomycin on Au-PtNPs/nanoPAN/ Chitosan Nanocomposite Membrane and Its Determination in Injections  被引量:3

Electrochemical Study of Lincomycin on Au-PtNPs/nanoPAN/ Chitosan Nanocomposite Membrane and Its Determination in Injections

在线阅读下载全文

作  者:WANG Xue-liang YANG Tao JIAO Kui 

机构地区:[1]College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, P. R. China

出  处:《Chemical Research in Chinese Universities》2010年第3期371-375,共5页高等学校化学研究(英文版)

基  金:Supported by the National Natural Science Foundation of China(Nos.20635020 and 20805025);Doctorial Foundation of the Ministry of Education of China(No.20060426001) ;Doctorial Fund of Qingdao University of Science and Technology, China(No.0022278)

摘  要:The Au-Pt alloy nanoparticles(Au-PtNPs) were electrochemically deposited on the surface of polyaniline nanotube(nanoPAN) and chitosan(CS) modified glassy carbon electrode(GCE). The electrochemical behavior of lincomycin at Au-PtNPs/nanoPAN/CS modified GCE was investigated by cyclic voltammetry, linear sweep voltammetry and chronocoulometry. Cyclic voltammetric experiments show that lincomycin at the nanocomposite membrane modified electrode exhibited a pair of quasi-reversible redox peaks in pH=6.0 PBS. The membrane could accelerate the electron transfer of lincomycin on the electrode and significantly enhance the peak current. In a range of 3.0-100.0 mg/L, the reductive peak current of lincomycin at 0.42 V was linearly related to its concentration and the linear regression equation was ip,c=0.2703ρ-0.0042(ip, c: μA; ρ: mg/L; r=0.998, n=7) with a detection limit of 1.0 mg/L(S/N =3). Compared with other methods, this method exhibited many advantages such as high sensitivity, selectivity, wide linear range and low detection limit. The method was used to determine the content of lincomycin in injections commercially available with satisfactory results. Some electrochemical parameters involved in the redox reaction of lincomycin, such as parameter of kinetic ha, standard rate constant ks and the number of H^+, were also calculated.The Au-Pt alloy nanoparticles(Au-PtNPs) were electrochemically deposited on the surface of polyaniline nanotube(nanoPAN) and chitosan(CS) modified glassy carbon electrode(GCE). The electrochemical behavior of lincomycin at Au-PtNPs/nanoPAN/CS modified GCE was investigated by cyclic voltammetry, linear sweep voltammetry and chronocoulometry. Cyclic voltammetric experiments show that lincomycin at the nanocomposite membrane modified electrode exhibited a pair of quasi-reversible redox peaks in pH=6.0 PBS. The membrane could accelerate the electron transfer of lincomycin on the electrode and significantly enhance the peak current. In a range of 3.0-100.0 mg/L, the reductive peak current of lincomycin at 0.42 V was linearly related to its concentration and the linear regression equation was ip,c=0.2703ρ-0.0042(ip, c: μA; ρ: mg/L; r=0.998, n=7) with a detection limit of 1.0 mg/L(S/N =3). Compared with other methods, this method exhibited many advantages such as high sensitivity, selectivity, wide linear range and low detection limit. The method was used to determine the content of lincomycin in injections commercially available with satisfactory results. Some electrochemical parameters involved in the redox reaction of lincomycin, such as parameter of kinetic ha, standard rate constant ks and the number of H^+, were also calculated.

关 键 词:LINCOMYCIN Au-Pt alloy nanoparticle Polyaniline nanotube Nanocomposite membrane 

分 类 号:O636.1[理学—高分子化学] TQ465[理学—化学]

 