低温地板辐射采暖埋管结构尺寸设计实验研究  被引量:3

Experimental Research on How to Design the Structure and Tube Size of Radiant Heating Low-temperature Floor

在线阅读下载全文

作  者:王丽 刘志铮[2] 王岳人[2] 

机构地区:[1]辽宁建筑职业技术学院,辽宁辽阳111000 [2]沈阳建筑大学,辽宁沈阳110168

出  处:《节能技术》2010年第1期11-14,共4页Energy Conservation Technology

摘  要:建立低温地板辐射采暖的传热模型,通过实测及理论计算,得出各表面之间的对流及辐射换热量,通过对换热表面的合理简化,得出地板辐射采暖表面温度与埋管层厚度、埋管间距的关系,为地板辐射采暖设计时确定埋管结构尺寸提供依据。The heat transfer model of the radiant heating low-temperature floor is established.Through our actual measurent and theoretical calculation,we obtained the surface's convection and the radiant transferring-heat.After simplifing the transferring-heat surface,we got the relations between surface temperature of the radiant heating of the floor and the thickness of the tube layer and tubes'pitches.It provides the evidence of the structure and the tube size when designing the radiant heating floor.

关 键 词:低温地板辐射采暖 传热模型 温度分布 埋管间距 埋深厚度 

分 类 号:TU832.16[建筑科学—供热、供燃气、通风及空调工程]

 