A/O生物铁法处理乙酰嘧啶废水污泥驯化及工艺研究  

STUDY ON A/O BIO-FERRIC PROCESS FOR THE TREATMENT OF ACETYL PYRIMIDINE WASTEWATER

在线阅读下载全文

作  者:安莹[1,2] 孙力平[1,2] 张浩[1,2] 李志伟[1,2] 

机构地区:[1]天津市水质科学与技术重点实验室,天津300384 [2]天津城市建设学院环境与市政工程系,天津300384

出  处:《水处理技术》2010年第6期85-89,共5页Technology of Water Treatment

基  金:国家水体污染控制与治理科技重大专项经费资助(2008ZX07314-004)

摘  要:采用缺氧/好氧生物铁法处理维生素B1厂中间产物乙酰嘧啶生产段实际废水,探讨了处理乙酰嘧啶废水的污泥驯化方法以及水力停留时间(HRT)、污泥负荷(Ns)、污泥龄(θc)、污泥回流比(R)以及硝化液内循环比(r)对生物处理效果的影响,得到了A/O生物铁法处理乙酰嘧啶废水的最佳工况条件:HRT为15h,Ns为0.28kgBOD.kg-1MLSS.d-1,θc为20d,R为100%,r为400%,且预处理后废水经A/O生物处理工艺使COD、TN及氨氮总去除率分别达到93.3%、81.7%及78.6%,出水pH为6.5~7.5。Anoxic/aerobic bio-ferric process was established to treat the wastewater of acetyl primidine which is the middle-production of vitamin B1. The methods of sludge acclimation and the effects of HRT,Ns,θc,R and r on removal efficiency of biological treatment process were discussed,while the optimal conditions were those:HRT was 15 h,Ns was 0.28 kgBOD·kg^-1MLSS·d^-1,θc was 20 d,R was 100% and r was 400%,the process which combined pretreatment with biological treatment has got the results that:total removal efficiency of COD、TN、NH4^+-N was 93.3%、81.7%、78.6%,respectively,and pH value was 6.6~7.5. It could make a significant foundation for the similar wastewater disposal in medical production and synthesis process.

关 键 词:乙酰嘧啶 维生素B1 A/O法 生物铁 

分 类 号:X787[环境科学与工程—环境工程]

 