检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李武帅[1] 彭春霖[1] 袁甫[1] 綦文娣[1]
机构地区:[1]中国科学院长春应用化学研究所
出 处:《光谱学与光谱分析》1999年第1期53-56,共4页Spectroscopy and Spectral Analysis
摘 要:本文将石油亚砜(简称PSO)浸渍在一种特制的吸附树脂上,用PSO为固定相的萃取色层法分离氧化钇中痕量稀土杂质,可以分析6~7N级的氧化钇样品,加入试验的回收率为67%~120%,相对标准偏差为±4.0%~19.4%。Petroleum sulfoxide NH 4SCN extraction chromatography was developed for the separation of Y from other rare earth elements.Some chromatographic parameters were chosen and separation factors between Y and other rare earth elements were determined.A column of resin coated with petroleum sulfoxide was used.The Y in the sample was eluted with NH 4SCN,then titrated with EDTA.The recovery was 67% 120% and relative standard deviation ±4 0% 19 4%.This method can be applied to the determination of trace amounts of rare earth impurities in Y 2O 3 with a purity of 99 999 9% 99 999 99%.