检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陈瑶刚[1] 赵明媚[1] 宁铁英[1] 刘伯晨[1]
机构地区:[1]青岛大学医学院第二附属医院神经外科,山东青岛266042
出 处:《河北医学》2010年第6期688-689,共2页Hebei Medicine
摘 要:目的:探讨分析人工脑膜在急诊颅脑手术中的疗效及应用价值。方法:回顾性分析我院65例行人工脑膜修补术的急诊颅脑手术患者,其中外伤性颅脑损伤43例,高血压脑出血22例,均行硬脑膜缺损修补术或扩大修补术,对其疗效、术后并发症及其随访结果进行分析。结果:全部病例术后头颅CT检查未见硬脑膜异常,其中并发脑膨出8例,脑积水4例,硬膜下积液5例,另外28例患者行Ⅱ期颅骨修补术时术中观察表明,人工脑膜封闭隔离保护脑组织的作用良好,炎症反应轻,解剖层次清晰。结论:急诊颅脑手术应用人工脑膜安全有效,可恢复原有解剖层次,显著降低各种并发症,缩短手术时间,提高手术成功率。Objective:To study the application of artificial dura in emergency craniocerebral surgery.Method:65 patients with artificial dura in emergency craniocerebral surgery were analysed retrospectively.Result:65 cases of operation with artificial dura in emergency craniocerebral surgery were successful.28 patients with stage Ⅱ cranioplasty showed that the artificial dura protected brain tissue well.Conclusion:The artificial dura in emergency craniocerebral surgery was safe and effective.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.188