浙江特高压交直流混合电网系统稳定性研究  被引量:12

A Study on the Stability of Zhejiang UHVAC and UHVDC Power Grid

在线阅读下载全文

作  者:毛雪雁[1] 孙黎滢[1] 徐政[2] 翁华[2] 华文[2] 

机构地区:[1]浙江省电力试验研究院,杭州310014 [2]浙江大学,杭州310027

出  处:《浙江电力》2010年第6期1-4,共4页Zhejiang Electric Power

摘  要:根据电网发展规划,"十二五"期间浙江电网将出现1000kV特高压交流输电工程和±800kV特高压直流输电工程同时投产的盛况。为此,从电压稳定、频率稳定、功角稳定等方面考察浙江特高压交直流混合电网的系统稳定性,评估不同直流落点对系统稳定性的影响,发现了浙江电网暂态稳定的薄弱区域和薄弱点,绘制了浙江电网交流故障引发直流故障的概率分布图,提出了研究结论与建议。According to the power grid development plan of State Grid Corporation,both 1 000 kV UHVAC and ±800 kV UHVDC transmission system will be put into operation in Zhejiang during 2011-2015.The paper evaluates the stability of Zhejiang UHVAC and UHVDC Power Grid,including voltage stability,frequency stability and power-angle stability.The effects of different locations of UHVDC inverter stations on the system stability are also analyzed.Weak areas and points of transient stability are discoverd and the probability graph of DC commutation failure caused by AC faults is shown.Finally,reseach conclusions and suggestions are given.

关 键 词:特高压 交直流混联 电压 频率 功角 稳定 

分 类 号:TM712[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象