摘 要:采用以微电子加工技术制作的微盘铂电极,将谷氨酸氧化酶用明胶包埋法固定在该微盘电极上,制成了性能稳定的微型谷氨酸传感器。实验测定了该传感器的最佳工作电位为550mV(vs.SCE),最适溶液pH值为pH=7。在所确定的工作条件下该传感器的线性范围为0.2—6mmol·L^(-1),检测灵敏度为150nA/mmol·L^(-1)。该传感器的使用寿命大于1个月。A glutamate microbiosensor is reported in this paper. According to the need of the commercialization of biosensors, the microelectronic technology was used in the fabrication of this glutamate sensor. Glutin was used to immobilize the glutamic acid oxidase on a microdisk thin film electrode. The sensor shows a good stability for long-term using. The optimal pH value of the solution for the sensor is around 7. At the working potential of 0. 55V(vs. SCE) , the sensor also shows a good sensitivity of 150 nA/mmol·L-1,and a linear response within the range of 0. 2 -6mmol·L-1.