摘 要:探讨了火电厂与抽水蓄能电站联合运行模式。分析了该模式的技术及经济可行性,并以宝山发电厂与宝泉抽水蓄能电站的联合运行为例,探讨了联合运行方案所产生的发电效益、节煤效益以及经济效益。对比发现,联合运行模式可有效降低抽水蓄能电站的上网电价,同时有助于系统节能减排的实现。Aiming at maximum utilization of pumped storage power station,stable economic operation of power system,joint operation mode is suggested.This paper analyses the joint mode of thermal power plant and the pumped storage station in the view of technology economy.Then by taking Baoquan pumped storage station as an example,comparison analysis is made between conventional operation mode and joint mode regarding generation benefit,coal-saving benefit and economy benefit as well.Result shows that joint operation can considerably bring down pool purchase price,and has obvious contribution on energy-saving and emission reduction.