检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李德奎[1] 刘跃[1] 朱名安[1] 程多智[1]
机构地区:[1]郧阳医学院附属太和医院检验部,湖北十堰442000
出 处:《医疗卫生装备》2010年第7期111-113,共3页Chinese Medical Equipment Journal
摘 要:目的:全面评估美国BECKMAN COULTER公司生产的ACLTOP全自动血凝分析仪。方法:从精密度、准确度、线性度、回收试验、抗干扰性及交叉污染率等方面对ACLTOP全自动血凝仪进行评估,并与ACL-Advance全自动血凝分析仪进行常规凝血指标比对。结果:ACLTOP全自动血凝分析仪的精密度、准确度、线性度、回收试验、抗干扰性及交叉污染率均较理想,与ACL-Advance的比对结果也较理想。结论:ACLTOP全自动血凝分析仪性能良好,所检测项目的结果可靠,完全能满足临床实验室的要求。Objective To evaluate comprehensively ACL TOP automated coagulation analyzer manufactured by American BECKMAN COULTER company.Methods The instrument was evaluated from the aspects of precision,accuracy,linear degree,recovery test,anti-interference and crossing pollution,and the results were compared with those by ACL-Advance.Results Precision,accuracy,linear degree,recovery test,anti-interference and crossing pollution of the instrument were reliable,and the comparison result with ACL-Advance was satisfying.Conclusion ACL TOP automated analyzer can meet the needs of clinical laboratories.
分 类 号:R318.6[医药卫生—生物医学工程] R446.11[医药卫生—基础医学]