摘 要:探讨改进基体溶液双道原子荧光光谱法测定食品样品中的汞。样品消解后用6mol/L盐酸、硫脲+抗坏血酸(50g/L)作为基体溶液进行仪器测定。本方法检出限0.051μg/g,最低检出质量浓度0.10μg/L,相对标准偏差为7.45%、6.76%,回收率为88.6%—113.2%。方法具稳定性好、灵敏度高、检出限低等优点。Improving on the matrix solution for the determination of mercury in foods by atomic fluorescence spectrophotometry (AFS) was discussed.The samples of foods were digested and analyzed by AFS in the matrix solution which was composed of 6mol/L hydrochloric acid,50g/L thiourea and 50g/L ascorbic acid.The limit of detection and the limit of concentration were 0.051μg/g and 0.10μg/L respectively.The average recoveries were from 88.6% to 113.2% with relative standard deviations (RSDs) were 6.76% and 7.45%.The method is simple,sensitivity,repeatability and can be applied for the analysis of mercury in foods.