75 t/h异型水冷分离循环流化床锅炉的设计运行  被引量:30

Design and Operation of 75 t/h CFBC Boiler with Square Water cooled Separator

在线阅读下载全文

作  者:吕俊复[1] 岳光溪[1] 刘青[1] 赵晓星[2] 刘艺[2] 叶学军[2] 

机构地区:[1]清华大学热能工程系 [2]四川锅炉厂

出  处:《中国电力》1999年第4期61-64,共4页Electric Power

摘  要:介绍了75t/h水冷异型分离循环流化床锅炉的设计参数、结构特点、关键部件、运行情况和存在的问题。采用异型水冷分离器的75t/h循环流化床锅炉比同容量的煤粉炉占地面积略小。第1批3台燃用不同燃料的锅炉的运行实践表明该炉燃料适应性强。密封性好,避免使用高温膨胀节。出力可以在铭牌的115%长期稳定运行,甚至超过120%。通过对有关参数的测量,确定了该炉的进一步完善方向并已实施。This paper introduces the design parameters, structure features, key components, operation and existing problems of 75 t/h CFBC boiler with square water cooled separator. Compared with the same capacity PC boiler, the 75 t/h CFBC boiler with square water cooled separator possesses less land area. The operation practice of the first three boilers burning different coals shown its good fuel adaptability, high tightnees, without necessity of using high temperature expansion joint. They could steadily operate at 115% or even at more than 120% of boiler's rating. Through measurements of related parameters, the further improvements were determined and some of them have been put into practice.

关 键 词:循环流化床锅炉 水冷分离 设计 运行 

分 类 号:TK229.66[动力工程及工程热物理—动力机械及工程] TK227

 