检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]福建工程学院环境与设备工程系,福建福州350108
出 处:《贵州大学学报(自然科学版)》2010年第3期140-142,共3页Journal of Guizhou University:Natural Sciences
摘 要:采集福州市某化工厂酚醛树脂生产废水,用微电解-Fenton试剂氧化-混凝沉淀工艺预处理,考察各影响因素对预处理效果的影响,并确定了工艺优化条件。结果表明:在进水CODcr浓度为56920 mg/L,pH为2.30,挥发酚浓度为1279 mg/L,甲醛浓度为12951 mg/L的条件下,Fe/C质量比4∶1,微电解反应时间1 h,H2O2投加量4 g/L,Fenton试剂氧化反应时间为1 h,混凝剂PAM的投加量为800 mg/L,pH为8.5的条件下,废水的CODcr总去除率为89.6%,挥发酚去除率为84.3%,甲醛去除率为98.5%,经过预处理后,酚醛树脂废水达到生化处理的要求。Treatment of wastewater containing phenol and formaldehyde in Fuzhou City was carried out by microelectrolys-Fenton oxidation-coagulation process.The influencing factors were investigated and the optimal working condition was sought for.Results show when the reaction time for the microelectrolysis is 1 h,pH is 2.3 0,the reaction time for the Fenton oxidation is 1h and the dosage of H2O2(30%) is 4 g/L,pH and mass concentration for coagulation are 8.5 and 800 mg/L,the removal rate of CODcr,phenol and formaldehyde are about 89.6 %,84.3 %,98.5 % respectively at the CODcr in influent 56920 mg/L,pH value 2.30,phenol 1279 mg/L,and formaldehyde 12951 mg/L,providing the good premise for the following biological treatment to remove.
分 类 号:X703[环境科学与工程—环境工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.30