大套第三抽水站辅助设备能耗计算分析  被引量:1

Calculation and analysis of auxiliary equipment dissipation energy in 3rd Datao pumping station

在线阅读下载全文

作  者:陆永泉[1] 朱庆元[1] 仇宝云[2] 杨兴丽[2] 冯晓莉[2] 董波[2] 

机构地区:[1]江苏省水利厅,江苏南京210029 [2]扬州大学能源与动力工程学院,江苏扬州225127

出  处:《排灌机械工程学报》2010年第4期340-343,共4页Journal of Drainage and Irrigation Machinery Engineering

基  金:全国优秀博士学位论文作者专项基金资助项目(2007B41);江苏省水利科技重点项目(2008031)

摘  要:为了解大型泵站辅助设备的能耗情况,以江苏省通榆河北延送水工程大套第三抽水站为例,介绍了大套第三抽水站辅助设备设置情况;通过分析各类辅助设备的运行情况,系统计算了辅助设备运行能耗,分析了各类辅助设备能耗的特点.结果表明,大套第三抽水站辅助设备耗能约占泵站总能耗的3.13%,其中,照明、清污和电机通风等能耗所占比例较大,各占辅助设备总能耗的1/3左右.成果可为大型泵站辅助设备的设计与节能提供参考.In order to know auxiliary equipment dissipate energy of a large pumping station,the 3rd Datao pumping station of Tongyu River north-extended water supply project in Jiangsu province was taken as an example,the auxiliary equipment in the 3rd Datao pumping station was introduced,the dissipation energy of the auxiliary equipment was calculated systematically by analyzing its operational aspect. The dissipation energy characteristics of the auxiliary equipment were analyzed. The results show that the dissipation energy of auxiliary equipment is about 3. 13% of the total dissipation energy of the pumping station,and the dissipation energy of illumination,trash removal and electric machine ventilation is comparatively large and shares about 1 /3 of total auxiliary equipment dissipation energy respectively. The results would provide references for the design and energy-saving of large pump station auxiliary equipment.

关 键 词:大套第三抽水站 泵站辅助设备 能耗 节能 

分 类 号:S277[农业科学—农业水土工程] TV735[农业科学—农业工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象