弱爆炸波吹灰器在大唐盘山电厂的应用  被引量:2

Application of weak blast wave soot-blowers in Datang Panshan Power Plant

在线阅读下载全文

作  者:张洪波[1] 

机构地区:[1]天津大唐国际盘山发电有限责任公司,天津301900

出  处:《中国电力》2010年第8期22-24,共3页Electric Power

摘  要:由于传统的蒸汽吹灰存在故障率高,吹灰效果差,蒸汽消耗大等特点,影响锅炉的安全经济运行。针对大唐盘山电厂3号锅炉空气预热器堵灰严重的问题,对空气预热器采用弱爆炸波吹灰器进行改造并获得成功。实践证明弱爆炸波吹灰器解决了空气预热器结灰不易清除的问题,保证了锅炉长期高效运行,达到了节能增效、安全生产的目的,可为同样存在空气预热器堵灰问题的电厂提供借鉴。The traditional steam soot blowing has the disadvantages of high failure rate, bad blowing effect and high steam consumption, which affect the safety and economic operation of boiler. In order to solve the dust block of air preheater, the weak blast wave soot-blowers was adopted in air prcheater. Practice has proved that the weak blast wave soot-blowers has solved the problem of removing ash difficultly in air preheater, which ensured the long-term efficient operation of boiler and achieved the purpose of energy conservation and safety production. It provided reference for power plants with dust block of air preheater fouling.

关 键 词:空气预热器 堵灰 吹灰器 弱爆炸波 运行分析 

分 类 号:TK223.27[动力工程及工程热物理—动力机械及工程]

 