出 处:《河北医学》2010年第8期911-913,共3页Hebei Medicine
摘 要:目的:探讨克氏针、钢板与锁定加压钢板在锁骨中段骨折中的应用价值。方法:对117例锁骨骨折内固定治疗,其中克氏针固定组59例,钢板组38例,锁定加压钢板组20例。结果:平均随访12.3个月,LCP和钢板骨折愈合优良率更高。结论:LCP和钢板治疗锁骨骨折效果好,克氏针适合于基层医院。Objective: To study the application value of Kirschner wire and plate and locked compress plate(LCP) in treatment of mediate clavicular fracture.Method: 117 cases with mediate clavicular fracture were treated with interior fixation,59 cases were fixed with Kirschner wire,38 cases were fixed with plate,20 cases were fixed with LCP.Result: The mean follow-up time was 12.3 months.Group of LCP and plate with higher of excellent and good rate being.Conclusion: LCP and plate help the mediate clavicular fracture recovered best,kirschner wire fit to the primary hospital.