中药废水两相厌氧生物处理工艺的工程调试  被引量:9

Commissioning of Two-phase Anaerobic Biological Process for Treatment of Traditional Chinese Medicine Wastewater

在线阅读下载全文

作  者:刘天顺[1] 闫险峰[2,3] 任南琪[2] 李建政[2] 闫从容 

机构地区:[1]天津市市政工程设计研究院,天津300051 [2]哈尔滨工业大学市政环境工程学院,黑龙江哈尔滨150090 [3]哈尔滨理工大学化学与环境工程学院,黑龙江哈尔滨150080 [4]平顶山市政公司,河南平顶山467000

出  处:《中国给水排水》2010年第16期119-121,125,共4页China Water & Wastewater

摘  要:中药生产废水具有污染物浓度高、可生化性差、水质水量波动大等特点,属于高浓度难降解有机工业废水。采用具有专利技术的两相厌氧生物处理工艺处理中药废水,调试结果表明,通过选取适当的接种污泥和制定合理的调试运行方案,可以保证两相厌氧工艺在3个月内完成工程调试,最终产酸相反应罐容积负荷为30~45kgCOD/(m3.d),COD去除率稳定在15%~20%;产甲烷相反应池容积负荷为8~10kgCOD/(m3.d),COD去除率稳定在90%~95%。Due to high concentration of pollutants, low biodegradability and large fluctuation in quality and quantity, traditional Chinese medicine wastewater is a high-concentration refractory wastewater. The two-phase anaerobic biological process with the patent technology was used to treat traditional Chinese medicine wastewater. The commissioning results show that the commissioning of two-phase anaerobic biological process can be completed within three months by selecting appropriate seeding sludge and establishing a reasonable commissioning scheme. The volumetric load of acidogenic reactor is 30 to 45 kg COD/(m^3 · d) and the removal rate of COD is 15% to 20%. The volumetric load of methanogenic reactor is 8 to 10 kgCOD/(m3 · d) and the removal rate of COD is 90% to 95% stably.

关 键 词:中药废水 两相厌氧 工程调试 

分 类 号:X703.1[环境科学与工程—环境工程]

 