摘 要:提出了高频炉燃烧-红外吸收光谱法测定高镍耐蚀合金中碳硫的方法,对试验条件进行了优化,选择钨锡混合助熔剂用量为0.6 g,样品称样量为0.5 g,碳的分析时间为35 s,硫的分析时间为60 s。取标准样品(IARM 67B,IARM 69C,IARM 60B)进行准确度和精密度试验,测定结果与认定值相符,碳和硫的相对标准偏差(n=10)分别小于4%和30%。A method for the determination of carbon and sulfur in high nickel corrosion resistant alloys by high frequency furnace combustion-IR spectrometry was proposed.The optimum experimental conditions were found as follow: ① amount of mixed flux of W and Sn: 0.6 g;② amount of sample: 0.5 g;③ analytical time for carbon: 35 s;④ analytical time for sulfur: 60 s.Tests for accuracy and precision were made with standard samples of IARM 67B,IARM 69C and IARM 60B,giving results in consistency with the standard values.Values of RSD′s(n=10) of carbon and sulfur found were less than 4% and 30%,respectively.