基于单纯形法触式探头传感器校准算法  被引量:1

Calibration algorithm of tactile probe sensor based on simplex method

在线阅读下载全文

作  者:李海艳[1] 李维嘉[1] 吴金波[1] 

机构地区:[1]华中科技大学船舶与海洋工程学院,湖北武汉430074

出  处:《武汉大学学报(工学版)》2010年第4期532-536,共5页Engineering Journal of Wuhan University

基  金:国家自然科学基金--青年科学基金(编号:60804050)

摘  要:针对测量系统机械部件的制造和装配存在误差等问题,提出了基于单纯形法触式探头传感器的校准算法,将传感器校准到通用坐标系中.该算法在充分分析触式探头传感器传感原理的基础上,用Fourier函数拟合探头测量路径,构造参数校准数学模型,并用单纯形法实现校准参数最优化.最后的实例结果显示用此算法校准后测量误差较小.Aiming at error from manufacturing and assembling in measurement system,an algorithm of tactile probe sensor calibrating is presented based on simplex method to calibrate the tactile probe to the common coordinate system.Based on adequately analyzing the sensing theory of tactile probe sensor,the algorithm builds the function of probe measurement path with Fourier function and sets the mathematic model for calibrating parameters;then the simplex method is used for optimizing the parameters.Finally,agiven example shows that the algorithm has smaller error.

关 键 词:触式探头传感器 校准 单纯形法 

分 类 号:TP73[自动化与计算机技术—检测技术与自动化装置]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象