活性氧化铝柱-气相色谱法测定工作场所空气中“四烯”的方法研究  被引量:1

DETERMINATION OF ETHYLENE,PROPYLENE,BUTYLENES AND BUTADIENE IN WORKPLACE AIR WITH ACTIVATED ALUMINA COLUMN AND GAS CHROMATOGRAPHY

在线阅读下载全文

作  者:杨万宗[1] 庄定利[1] 许红林[1] 

机构地区:[1]中国石化扬子石油化工有限公司安全环境健康部HSE监测站,南京210048

出  处:《化学分析计量》2010年第5期38-41,共4页Chemical Analysis And Meterage

摘  要:采用活性氧化铝柱-气相色谱法对作业场所空气中乙烯、丙烯、丁烯、丁二烯进行活性炭采样,热解吸后进样分析。活性炭管对"四烯"的吸附性良好,测定结果的相对标准偏差为0.37%~2.08%;乙烯、丙烯、丁烯、丁二烯检出限分别为0.0010、0.000520、.00083、0.0003 mg/L;样品的平均解吸效率为93.7%~98.59%;样品的平均采样效率为93.9%~99.1%;乙烯、丙烯、丁烯、丁二烯穿透容量分别为9.58、.87、.4、7.1 mg;样品在室温下放置7 d,其平均样品损失率不大于5.58%,在4~10℃环境放置10 d,其平均样品损失率不大于7.11%,空气中乙烷对本方法无干扰。该法可满足职业卫生检测的要求。Ethylene, propylene, butylenes and butadiene in workplace air were determined by activated alumina column and gas chromatography. The samples collected by active carbon were analysed after thermal desorption., Active carbon tube had good adsorbability with relative standard deviation of 0.37% -2.08%. The lowest determination limits for ethylene, propylene, butylenes and butadiene were 0. 001 0, 0. 000 52, 0. 000 83, 0. 0003 mg/L, respectively. The average desorption rate of sample was 93.7% - 98.59%. The average sampling efficiency of the sample was 93.9% -99.1%. The breakthrough capacity of ethylene, propylene, butylene, butadiene were 9.5, 8.8, 7.4, 7.1 mg, respectively. The average loss rate of the sample was not more than 5.58% when they were placed at room temperature for 7 d and not more than 7.11% when they were placed at environment temperature of 4 - 10℃ for 10 d. The ethane in air had no influence on this method. This method is satisfied for the requirement of occupational health detection.

关 键 词:活性氧化铝 气相色谱法 工作场所 乙烯 丙烯丁烯丁二烯 

分 类 号:O657.71[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象