摘  要:为了降低空调能耗,文中以水源制冷机房为模型,分析了影响制冷机房总能耗的主要运行参数,然后采用正交试验法对制冷机房在不同参数条件下的能耗进行了模拟,找到了各运行参数影响制冷机房总能耗和单位冷量能耗的主次顺序及基本规律。In order to reduce air-conditioning energy consumption,taking water-source chilled water plant as a model to analyze the impact of operating parameters on the total energy of the chilled plant.Then the energy consumption was simulated and analyzed under different conditions through orthogonal experiments.Results show the primary and secondary order and the basic law of operating parameters affect the total energy consumption and the energy consumption unit cooling capacity.

关 键 词:制冷机房 运行参数 能耗 