测量气体绝缘变电站中快速暂态过电压的微分积分方法  被引量:19

DIFFERENTIATING/INTEGRATING SYSTEM FOR THE MEASUREMENT OF VERY FAST TRANSIENT OVERVOLTAGES IN GIS

在线阅读下载全文

作  者:史保壮[1] 张文元[2] 邱毓昌[2] 

机构地区:[1]广东省电力试验研究所 [2]西安交通大学

出  处:《中国电机工程学报》1999年第5期59-61,29,共4页Proceedings of the CSEE

摘  要:提出了一种新的快速暂态过电压(VFTO)测量方法——微分积分方法,其特点是不需对GIS作任何改造。在同轴传输单元上对研制的微积分系统的响应特性进行了校验,并首次在国内500kV的GIS上进行了VFTO实测,测量结果与分析计算一致,表明微积分系统是一种较好的VFTO测量方法。A differentiating/integrating(D/I) system, which does not change Gas Insulated Substation(GIS) configuration, is developed for the field measurement of Very Fast Transient Overvoltages(VFTO) occurring in GIS. The D/I system transfer characteristics are measured on a coaxial transmission system. Step response experiments show ideal performance of the D/I system. VFTO is measured using the D/I system in a 500kV GIS. Field VFTO measurements show that the D/I system has the advantages of not influencing GIS service and convenient installation.

关 键 词:气体绝缘 变电站 过电压 测量 VFTO 微分积分法 