检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]北京建筑工程学院,北京100044 [2]北京市燃气集团有限责任公司,北京100035
出 处:《煤气与热力》2010年第10期36-40,共5页Gas & Heat
摘 要:论述了城市埋地天然气管道泄漏事故的原因和后果。建立了火灾危险区域计算关系式,结合北京市近年来典型的管道事故,对事故后果的主要影响因素(管道运行压力、管道破损面积等)进行了定量分析。火灾危险区域半径大于城镇燃气设计规范中规定的管道距建筑物的最小距离,管道运营公司应当加强与公众及第三方施工单位的联系,降低管道泄漏及火灾风险。The causes and consequences of leakage accidents for urban buried natural gas pipeline are expounded. The relational expression for fire danger area is established. Combined with typical pipeline accidents during recent years in Beijing City, the main influencing factors of the accident consequences, such as pipeline operating pressure, pipeline breakage area and so on, are quantitatively analyzed. The fire danger area radius is larger than the minimum distance between pipeline and building required in Code for Design of City Gas Engineering. The pipeline operating companies should strengthen the relationship with public and third party construction organization to reduce pipeline leakage and fire risk.
关 键 词:天然气管道 事故 泄漏后果 风险评价 火灾危险区域预测 安全管理
分 类 号:TU996[建筑科学—供热、供燃气、通风及空调工程]