机构地区:[1]山西省临汾市中心血站,041000
出 处:《临床输血与检验》2010年第4期318-320,共3页Journal of Clinical Transfusion and Laboratory Medicine
摘 要:目的对无偿献血者血标本进行HBsAg检测时,分析血液保养液(CPD)与肝素抗凝剂对结果的影响。方法取4IU/mlHBsAg质控品,分别制备成不同的待检样本,即肝素抗凝剂组(对照组)和CPD保养液组(实验组);应用ELISA试剂盒检测两组样本HBsAg,将所得S/CO值进行配对t检验。结果对照组S/CO值为8.81,实验组S/CO值为7.60,差异有统计学意义(t=5.67,P<0.05)。结论采用ELISA法检测HBsAg时,含CPD保养液的样本比肝素抗凝剂样本结果的S/CO值低,应引起采供血机构的重视。Objective To investigate the influence of preservative(CPD) and heparin anticoagulant on results of HB- sAg ELISA when samples were collected from voluntary blood donors. Methods Quality control material of HBsAg (4 IU/ml) was prepared for samples of two groups:anticoagulant heparin (experiment group), CPD preservative (control group) . Samples of two groups were inspected using ELISA agent kits for HBsAg and the values of S/CO were analysed by paired t-test. Result The value of the control group S/CO was 8.81 ,and that of the experiment group was 7.60. The difference was signifcant (t: 5.67,P〈0.05). Conclusion The values of samples with CPD were lower than with anticoag- ulant heparin when HBsAg was detected with ELISA. Blood collection and supply agencies should give enough considera- tion for this factor when coped with the blood samples whose initial ELISA reaction were positive.