A Clock Enhanced Loop for Simultaneous Error-Free Demultiplexing and Clock Recovery of 160Gb/s OTDM Signal Single-Channel Transmission over 100km  

A Clock Enhanced Loop for Simultaneous Error-Free Demultiplexing and Clock Recovery of 160Gb/s OTDM Signal Single-Channel Transmission over 100km

在线阅读下载全文

作  者:贾楠 李唐军 钟康平 王目光 陈明 李晶 池剑锋 

机构地区:[1]Key-Laboratory of All-Optical Networks and Advanced Communication Networks (Ministry of Education) Beijing Jiaotong University, Beijing 100044 [2]Institute of Light Wave Technology, Beijing Jiaotong University, Beijing 100044

出  处:《Chinese Physics Letters》2010年第11期121-124,共4页中国物理快报(英文版)

基  金:Supported by the Fundamental Research Funds for the Central Universities (No 2009YJS005), the National High-Tech Research and Development Program of China under Grant No 2008AA01Z15, the National Natural Science Foundation of China under Grant No 60877042 and 60837003, Beijing Nova Program (No 2008A026), and the Natural Science Foundation of Beijing (No 4062027).

摘  要:A simple clock enhanced loop of cascaded electro-absorption modulators (EAMs) and 10 GHz clock recovery modules is presented. The intensity of harmonic of clock-frequency component is analyzed theoretically and verified experimentally in a 160 Gb/s OTDM 100 km transmission system. The 10 GHz clock component is enhanced obviously before launching into the clock recovery module and the recovered clock signal exhibits low rms jitter of 〈400 fs. Moreover, completely error^-1free (10-12) transmission is observed for more than two hours without using forward error correction technology. The power penalty is about 3.6 dB. The proposed loop has merits of enhancing base clock component, simultaneously de-multiplexing and clock recovery, which make the performance of this loop more stable and high suppression of non-target channels.A simple clock enhanced loop of cascaded electro-absorption modulators (EAMs) and 10 GHz clock recovery modules is presented. The intensity of harmonic of clock-frequency component is analyzed theoretically and verified experimentally in a 160 Gb/s OTDM 100 km transmission system. The 10 GHz clock component is enhanced obviously before launching into the clock recovery module and the recovered clock signal exhibits low rms jitter of 〈400 fs. Moreover, completely error^-1free (10-12) transmission is observed for more than two hours without using forward error correction technology. The power penalty is about 3.6 dB. The proposed loop has merits of enhancing base clock component, simultaneously de-multiplexing and clock recovery, which make the performance of this loop more stable and high suppression of non-target channels.

关 键 词:Electronics and devices Optics quantum optics and lasers 

分 类 号:TN929.1[电子电信—通信与信息系统] TP334.7[电子电信—信息与通信工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象