检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]浙能乐清发电有限责任公司,浙江乐清325609 [2]安阳市市政设计研究院有限责任公司,河南安阳455000 [3]河海大学环境学院,江苏南京210098
出 处:《环境科学与管理》2010年第10期83-86,共4页Environmental Science and Management
摘 要:为了探讨废水中无机阴离子对电化学氧化降解对氯苯酚(4-CP)产生的影响。文章采用了自制圆形电化学反应器,通过改变模拟废水中电解质及其浓度来分析无机阴离子对4-CP去除率及矿化率的影响。试验研究表明,当废水中以OH-为主且浓度约为0.01 mol/L时,4-CP去除率可达81.99%,矿化率最高可达38.09%,而电化学能耗最低仅为35.57 kWh。P-Chlorphenol was selected as a model pollution substrate.The influences of inorganic anions on its degradation were investigated in the wastewater by changed the supporting electrolyses and its concentration at ambient temperature and pressure.Results showed that 4-CP could be removed efficiently by electrical chemistry oxidation with 81.99% removal rate when the concentration of OH-was about 0.01 mol/L in 2.5hours,the mineralization rate of 4-CP was up to 38.90%,and the electrochemical energy consumption was the lowest that was just only 35.57 kWh/(kg4-CP).
关 键 词:无机阴离子 电化学氧化 对氯苯酚 电化学能耗 废水处理
分 类 号:X781[环境科学与工程—环境工程]