胶原在聚乳酸旋涂膜表面的吸附研究  被引量:2

ADSORPTION BEHAVIOR OF COLLAGEN ON THE SPIN-COATED PLA SURFACE

在线阅读下载全文

作  者:胡安珍[1] 史济斌[1] 戎宗明[1] 薛平[1] 龚飞荣[2] 程树军[2] 

机构地区:[1]华东理工大学化学与分子工程学院化学系,上海200237 [2]华东理工大学材料科学与工程学院,上海200237

出  处:《高分子学报》2010年第11期1262-1268,共7页Acta Polymerica Sinica

基  金:国家高技术研究发展计划(863计划;项目号2007AA02Z450)资助项目

摘  要:采用石英晶体微天平(QCM)、原子力显微镜(AFM)研究了胶原在聚乳酸旋涂膜表面的吸附,考察了溶液浓度(0~9.25μg/mL)和温度(10~50℃)对胶原吸附的影响.实验结果表明,随着胶原浓度的增加,胶原在聚乳酸表面的吸附量和吸附初速率都相应增加.采用Langmuir模型和Freundlich模型拟合实验数据得到吸附等温线方程,分别为q=11690.99c1+0.99c和q=610c3.179.实验结果显示,Langmuir模型拟合效果要好于Freundlich模型.采用Lagergren拟一阶吸附速率方程和Lagergren拟二阶速率方程拟合不同浓度下的吸附动力学数据.在低浓度下Lagergren拟一阶速率方程拟合效果比较好,在高浓度下Lagergren拟二阶速率方程拟合效果比较好,说明在低浓度时扩散过程是胶原吸附的控速步骤,高浓度时胶原和聚乳酸表面的相互作用是吸附的控速步骤.原子力显微镜显示,吸附在聚乳酸表面的胶原形成网状结构.胶原的吸附受温度影响显著,说明胶原是一种对温度非常敏感的物质.实验结果表明随着温度的升高,在10~40℃范围内胶原的吸附量逐渐降低,在40~45℃范围内锐减,40℃是本实验条件下胶原的变性温度.The adsorption of collagen on spin-coated poly(lactic acid) (PLA) surface was investigated using quartz crystal microbalance (QCM). The effects of concentration (0 ~ 9. 25 μg /mL) and temperature (10 ~ 50℃ ) on adsorption were studied. The results show that: with the increasing concentration of collagen,the adsorption amount and initial adsorption rate on spin-coated PLA surface increases correspondingly. Langmuir model and Freundlich model were applied for data fitting. The isotherm equations q = 1169 0. 99c1 + 0. 99c and q = 610c 1 3. 79 were obtained. It is found that Langmuir model described experiments better than the Freundlich model. The kinetic experimental data were correlated with the Lagergren pseudo-first order kinetic model and the Lagergren pseudo-second order kinetic model. It is shown that under low concentrations the Lagergren pseudo-first order kinetic model fits the results better and the Lagergren pseudo-second order kinetic fits the results better under high concentrations. It means that the diffusion process is the rate-controlling step under low concentration and the interaction between collagen and PLA surface is the rate-controlling step under high concentrations. The AFM images show that the collagen adsorbed on PLA surface formed mesh-like structure. The adsorption was significantly influenced by temperature changes in the adsorption buffer,indicating that the collagen is a kind of temperature-sensitive material. The results also indicate that collagen denaturalizes gradually with increasing temperature in the range (10 ~ 40℃ ). The adsorption quantity drops sharply when the temperature approaches (40 ~ 45℃ ),40℃ is the denaturizing temperature of collagen under present experimental conditions.

关 键 词:吸附 石英晶体微天平 胶原 聚乳酸 

分 类 号:R318.08[医药卫生—生物医学工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象