Fenton法处理反渗透浓缩液的研究  被引量:11

Research on the concentrated solution of reverse osmosis by Fenton

在线阅读下载全文

作  者:郭琇[1,2] 孙宏伟[2] 

机构地区:[1]中山大学化学与化学工程学院,广东广州510275 [2]仲恺农业工程学院环境科学与工程学院,广东广州510225

出  处:《工业水处理》2010年第10期64-66,共3页Industrial Water Treatment

摘  要:采用Fenton法进行了反渗透浓缩液的处理实验,研究表明:单独使用UV不能有效去除废水中的有机物,也不能去除色度;采用UV+H2O2+铁粉工艺和三维电极+铁粉工艺实验时,在pH=3,废水中的COD的去除率可达30%以上,同时有很好的脱色效果;而且三维电极+铁粉工艺随着时间的推移,其处理效果有所增加。通过实验确定了最佳处理参数,同时对其反应机理进行了探讨。Fenton process has been used for treating the concentrated solution of reverse osmosis.It shows that using UV singly could not remove the organisms from wastewater and chroma efficiently.But using the UV,UV+ H2O2+Fe powder and three-dimensional electrode + Fe powder process,when its pH = 3,the COD removal rate in wastewater can reach 30%,and quite good decolorization result can be obtained.With the time going on,the treatment effect can be even better.Based on experiments,the optimal treatment parameters have been found.And its reaction mechanisms have been discussed.

关 键 词:高级氧化技术 FENTON法 反渗透浓缩液 

分 类 号:X703.1[环境科学与工程—环境工程]

 