工业冷却水中除锰、除铁的试验研究  被引量:3

Experiment and Research on the Mn and Fe Removal from Industrial Cooling Water

在线阅读下载全文

作  者:胡国强 许胜先 

机构地区:[1]辽阳石油化工高等专科学校

出  处:《给水排水》1999年第6期41-43,共3页Water & Wastewater Engineering

摘  要:研究了无烟煤-石英砂滤料接触氧化法除工业冷却水中锰、铁的工艺条件。滤料粒径05mm~10mm,滤床高800mm(无烟煤、石英砂滤料各400mm),滤速10m/h~12m/h,工作周期96h,反冲洗强度10L/(m2·s),反冲洗时间5min~7min,出水Mn2+浓度为004mg/L以下,去除率可达90%以上,总铁浓度为痕量。Abstract This paper focuses on the research of a process to remove manganese and iron from the industrial cooling water by contact oxidation process using natural filtering media of anthracite and quartzite. The operating parameters are: size of filTering maTerial 0.5 to 1.0 mm, filtering bed height 800mm, filtering speed 10 to 12 m/h, working cycle 96 hours, backwashing strength 13 L/(m 2·s) and backwashing time 5 to 7 min. In the treated water the residual Mn 2+ concentration is below 0.04mg/L with removal ratio up to 90% and the total Fe is trace level.

关 键 词:工业冷却水 无烟煤 石英砂 滤料 除锰 除铁 

分 类 号:TQ085.41[化学工程] TU991.4[建筑科学—市政工程]

 