摘  要:目的:探讨苯扎溴铵器械消毒液的保存期限。方法:选择10个批号自制苯扎溴铵器械消毒液,常温密封遮光保存,分别测定第1,3、6、9、12、15、18、21天苯扎溴铵器械消毒液的PH值和苯扎溴铵的含量。结果:15天后PH值改变不大而苯扎溴铵含量变化很大。结论:苯扎溴铵器械消毒液的有效期为15天。Aim: To find out the retention period of Benzene Bromide Disinfecting Solution for Equipment. Methods: 10 hatches of self-made Disinfecting Solution was preserved at Shading kept sealed at room temperature. Testing for pH value and content of Benzene Bromide was conducted at 1, 3, 6, 9, 12, 15, 18 and 21 day repectively. Results: There was slight change in pH value, whereas a great change in the content of benzene bromide after 15 days. Conclusion: The period of validity for Benzene Bromide Disinfecting Solution for Equipment was 15 days.

关 键 词:苯扎溴铵 器械 消毒液 稳定性 