检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杜翠娟
机构地区:[1]广东省电子电器产品监督检验所,广州510400
出 处:《化学分析计量》2010年第6期69-70,共2页Chemical Analysis And Meterage
摘 要:采用微波消解法进行溶样,以ICP—AES法测定塑料中Pb和Cd的含量。Pb、Cd的回收率分别为96.0%~102.0、93.3%~105.0%。Pb、Cd测定结果的相对标准偏差分别为0.567%、1.19%(n=10)。Ph和cd的检出限分别为0.02、0.005mg/L。该方法适用于多种塑料中Ph和Cd含量的快速分析。Lead and cadmium in plastic were analyzed by microwave digestion - ICP - AES. The recoveries of Pb and Cd were 96.0% - 102.0, 93.3% - 105.0% respectively. The RSD of Pb and Cd were 0. 567%, 1.19% (n = 10) respectively. The de- tection limits of Pb and Cd were 0.02, 0. 005 mg/L respectively. The resuhs showed that this method was accurate and could be used to analyze content of Pb and Cd in plastic materials.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.7