Adjusted Scheme of the Axial Injection Line for CRM  

Adjusted Scheme of the Axial Injection Line for CRM

在线阅读下载全文

作  者:YAO Hong-juan,LI Zhen-guo,LU Yin-long,GE Tao,WU Long-cheng,ZHONG Jun-qing 

出  处:《Annual Report of China Institute of Atomic Energy》2009年第1期43-44,共2页中国原子能科学研究院年报(英文版)

摘  要:In 2009,during the beam test of the CRM (Central Region Model) cyclotron,we found that the quadrupoles placed on the axial injection line could not work lis expected,so it was predicated thatIn 2009, during the beam test of the CRM (Central Region Model) cyclotron, we found that the quadrupoles placed on the axial injection line could not work lis expected, so it was predicated that the problem occurs due to the quadrupoles. Therefore, the two quadrupoles were removed from the injection line and the magnetic field of quadrupoles was measured. The intensities of magnetic field of four poles of quadrupoles were 160, 115, 80 and 110 Gs respectively, so the magnetic field was poorly asymmetric.