出  处:《中国给水排水》2010年第22期61-63,共3页China Water & Wastewater

摘  要:一层小店面消火栓箱的布置关系到建筑外立面的美观及以后的管理维护。结合设计和工程实践,建议小店面消火栓设在室外墙上,且不带水龙带;提倡住宅设双立管双阀双出口型消火栓;建议借鉴美国等国家的做法,将消火栓设在封闭楼梯间内。The layout of hydrant box for small single storey shop affects the appearance of building facade and subsequent maintenance management. Combined with the design and engineering practice, it is recommended that the hydrant box for small single storey shop is located at outdoor wall, without hose. It is promoted that a double stack two-valve double outlet hydrant is set in a residence. Using the practice in the United States and other countries for reference, the fire hydrant can be set in enclosed stairway.

关 键 词:消火栓箱 一层小店面 双立管双阀双出口型消火栓 水龙带 水枪 

分 类 号:TU892[建筑科学]

 