Clinical outcomes and cost-utility after sirolimus-eluting versus bare metal stent implantation  

Clinical outcomes and cost-utility after sirolimus-eluting versus bare metal stent implantation

在线阅读下载全文

作  者:ZHAO Fu-hai LU Shu-zheng LI Hui NING Shang-qiu YUAN Fei SONG Xian-tao JIN Ze-ning ZHOU Yuan CHEN Xin LIU Hong TIAN Rui MENG Kang LI Hong HAN Feng 

机构地区:[1]Department of Cardiology,Beijing Anzhen Hospital,Capital Medical University,Beijing 100029,China [2]Department of Cardiology,Beijing Anzhen Hospital,Capital Medical University,Beijing 100029

出  处:《Chinese Medical Journal》2010年第20期2797-2802,共6页中华医学杂志(英文版)

摘  要:Background Randomized studies have shown beneficial effects of drug-eluting stent (DES) in reducing the risk of repeated revascularization. Other studies have shown higher proportion of death, myocardial infarction (MI) and increased cost concerning DES. However the long term safety and effectiveness of DES have been questioned recently.Methods To compare long term clinical outcomes, health-related quality of life (HRQOL) and cost-utility after sirolimus-eluting stent (SES) and bare metal stent (BMS) implantation in angina patients in China, 1241 patients undergoing percutaneous coronary revascularization (PCl) with either SES (n=632) or BMS (n=609) were enrolled continuously in this prospective, nonrandomized, multi-center registry study.Results Totally 1570 stents were implanted for 1334 lesions. Follow-up was completed in 1205 (97.1%) patients at 12 months. Rates of MI, all causes of death were similar between the two groups. Significant differences were found at rate of cardiovascular re-hospitalization (136 (22.4%) in BMS group vs. 68 (10.8%) in SES group, P=0.001) and recurrent angina (149 (24.5%) vs. 71 (11.3%), P=0.001). Dramatic difference was observed when compared the baseline and 9-month HRQOL scores intra-group (P 〈0.001). However no significant difference was found inter-group either in baseline or follow-up HRQOL. Compared with SES, the total cost in BMS was significantly lower on discharge (62 546.0 vs. 78 245.0 Yuan, P=0.001). And follow-up expenditure was remarkably higher in the BMS group than that in the SES group (13 412.0 vs. 8 812.0 Yuan, P=0.0001).Conclusions There were no significant differences on death, in-stent thrombosis, MI irrespective of stent type. SES was superior to BMS on improvement of life quality. SES was with higher cost-utility compared to BMS.Background Randomized studies have shown beneficial effects of drug-eluting stent (DES) in reducing the risk of repeated revascularization. Other studies have shown higher proportion of death, myocardial infarction (MI) and increased cost concerning DES. However the long term safety and effectiveness of DES have been questioned recently.Methods To compare long term clinical outcomes, health-related quality of life (HRQOL) and cost-utility after sirolimus-eluting stent (SES) and bare metal stent (BMS) implantation in angina patients in China, 1241 patients undergoing percutaneous coronary revascularization (PCl) with either SES (n=632) or BMS (n=609) were enrolled continuously in this prospective, nonrandomized, multi-center registry study.Results Totally 1570 stents were implanted for 1334 lesions. Follow-up was completed in 1205 (97.1%) patients at 12 months. Rates of MI, all causes of death were similar between the two groups. Significant differences were found at rate of cardiovascular re-hospitalization (136 (22.4%) in BMS group vs. 68 (10.8%) in SES group, P=0.001) and recurrent angina (149 (24.5%) vs. 71 (11.3%), P=0.001). Dramatic difference was observed when compared the baseline and 9-month HRQOL scores intra-group (P 〈0.001). However no significant difference was found inter-group either in baseline or follow-up HRQOL. Compared with SES, the total cost in BMS was significantly lower on discharge (62 546.0 vs. 78 245.0 Yuan, P=0.001). And follow-up expenditure was remarkably higher in the BMS group than that in the SES group (13 412.0 vs. 8 812.0 Yuan, P=0.0001).Conclusions There were no significant differences on death, in-stent thrombosis, MI irrespective of stent type. SES was superior to BMS on improvement of life quality. SES was with higher cost-utility compared to BMS.

关 键 词:sirolimus-eluting stent bare metal stent clinical outcomes COST-UTILITY health-related quality of life 

分 类 号:Q492.6[生物学—生理学] TD353.2[矿业工程—矿井建设]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象