一台自耦变压器起动两台电动机的方法  

Methods of One Autotransformer Starting Two Electromotors

在线阅读下载全文

作  者:刘泽西[1] 王勇[1] 谢新萍[1] 

机构地区:[1]西北核技术研究所,陕西西安710024

出  处:《电工电气》2010年第11期43-45,共3页Electrotechnics Electric

摘  要:为了克服传统电动机自耦降压起动的缺点,采用自耦降压起动柜前移和改变正常运行接触器逻辑位置两种方法,实现了一台自耦变压器起动两台电动机,达到了减少起动设备数量、提高设备利用率、节约经费的目的。通过对两种起动方法的组装调试,运行稳定可靠,证明设计是成功的。To avoid disadvantages of the auto-induction voltage-reduced start-up of conventional electromotors, this paper adopted two methods which were forwarding the autotransformer and changing the logical placement of working contactor to realize one autotransformer controlling two electric engines, so as to reduce the number of the start-up equipment and save the expenditure, rais- ing the equipment utilization. The two mehtods pass the assembling test and the improved system runs stably and reliably, which are proved to be successful design.

关 键 词:自耦变压器 起动 电动机 

分 类 号:TM411.3[电气工程—电器]

 