检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:周月桂[1] 窦文宇[1] 周屈兰[1] 徐通模[1] 惠世恩[1]
机构地区:[1]西安交通大学
出 处:《动力工程》1999年第3期7-10,共4页Power Engineering
基 金:机械部技术发展基金
摘 要:对引进型600MW 机组四角切向燃烧锅炉进行冷态模化试验,系统地研究了不同折焰角结构对水平烟道烟速偏差的影响。试验结果表明:在现有的折焰角结构下水平烟道仍存在较大的气流速度不均匀性。通过折焰角结构进行改进,可以明显减小水平烟道气流速度场的不均匀性,为解决大容量四角切向燃烧锅炉水平烟道流场偏差这一重大技术问题提供了有价值的科学实验数据。Cold modeling test is done in the model of tangentially fired boiler of 600MW unit and the influence of different arch structures on velocity deviation in flue gas channel is systematically researched. The results show that there is large velocity deviation in original arch structure of boilers. Based on original arch structure, new arch structure is put forward and it may obviously meliorate non uniformity of flow field in flue gas channel. It provides valuable scientific experimental data for solution of velocity deviation in flue gas channel of large scale tangentially fired boiler and gives reference to the design and retrofit of boilers. Figs 2, tables 3 and refs 5.
分 类 号:TK223.2[动力工程及工程热物理—动力机械及工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49