Fenton氧化法深度处理草浆造纸废水的研究  被引量:23

Study on the advanced treatment of pulp and papermaking wastewater by Fenton oxidation

在线阅读下载全文

作  者:杨丽云[1,2] 李怡帆[2] 孙剑辉[2] 

机构地区:[1]新乡学院化学与化工学院,河南新乡453003 [2]河南师范大学化学与环境科学学院,河南省环境污染控制重点实验室,河南新乡453007

出  处:《工业水处理》2010年第11期59-62,共4页Industrial Water Treatment

基  金:河南省重点科技攻关项目(102102310244);河南省基础与前沿技术研究项目(102300410098)

摘  要:采用Fenton氧化法深度处理经厌氧、好氧处理后的草浆造纸废水,通过正交实验和单因素试验,研究了各主要因素对废水CODCr去除效果的影响,确定了最佳工艺条件。结果表明:在进水CODCr为415 mg/L、pH=3、H2O2投加量为30 mmol/L、Fe2+投加量为5 mmol/L、反应时间为50 min时,废水CODCr的去除率达85.49%,出水CODCr降到61 mg/L以下。Fenton oxidation process has been used for treating pulp and papermaking wastewater,which was treated by anaerobic and aerobic processes.Based on the orthogonal test and single factor test,the effects of every main factor on CODCr removal rate are investigated.Thus the optimal conditions are determined.The results show that the wastewater CODCr reaches 85.49% and the effluent CODCr is below 61 mg/L,when the influent CODCr is 415 mg/L,pH=3,H2O2 dosage is 30 mmol/L,Fe2+ dosage is 5 mmol/L,and reaction time is 50 min.

关 键 词:FENTON氧化法 草浆造纸废水 深度处理 

分 类 号:X703.1[环境科学与工程—环境工程]

 