摘 要:本文就发生炉煤气站煤气放散系统及其规范设计要求进行了简要阐述,对煤气放散系统放散管通径和放散高度的合理设计进行了分析探讨,并结合煤气放散引发的几个事故案例,对与煤气放散系统相关的设备及管道系统的安全设计进行了系统分析,同时指出煤气放散系统对维持发生炉煤气站的安全生产至关重要,煤气放散系统及相关设备的规范设计应该受到设计人员的高度重视。In this paper,a brief introduction on the gas discharge system in gas station as well as design standard was made firstly,then the rationality of discharge pipe drift diameter and discharge height design was analyzed and discussed.St also combined with the accident case which cause by gas discharge to systematic analyze the safety design of gas discharge equipment and the pipe system. It pointed out that the gas discharge system took an important part in gas station operation safety. The designer should pay more attention on the standard design of gas discharge system and relative equipment.
关 键 词:发生炉煤气站 煤气放散系统 煤气管道系统 放散管通径 放散高度 水封 安全设计