Effect of a dual-function solar collector integrated with building on the cooling load of building in summer  被引量:5

Effect of a dual-function solar collector integrated with building on the cooling load of building in summer

在线阅读下载全文

作  者:JI Jie LUO ChengLong SUN Wei HE Wei JIANG QingYang 

机构地区:[1]Department of Thermal Science and Energy Engineering, University of Science and Technology of China, Hefei 230026, China

出  处:《Chinese Science Bulletin》2010年第31期3626-3632,共7页

基  金:supported by the National Natural Science Foundation of China (50876098);the National Key Technology R&D Program of China (2006BAA04B04)

摘  要:As a building integrated solar thermal system,the dual-function solar collector integrated with building works for passive space heating in cold winter season,and for water heating in warm seasons.In this paper,the study is made on the dual-function solar collector integrated with building when it works in water heating mode with natural circulation.The coupled model of the collector and building's environment is established and validated.A numerical simulation is achieved to show the thermal effect of the novel system on the building in summer.By comparing with the cooling loads of the rooms with or without the novel collector in summer,the results show that when in summer,the novel solar system is available for serving hot water,and it does not have the summer overheating problem,and can even improve the thermal environment of its building slightly.As a building integrated solar thermal system, the dual-function solar collector integrated with building works for passive space heating in cold winter season, and for water heating in warm seasons. In this paper, the study is made on the dual-function solar collector integrated with building when it works in water heating mode with natural circulation. The coupled model of the collector and building's environment is established and validated. A numerical simulation is achieved to show the thermal effect of the novel system on the building in summer. By comparing with the cooling loads of the rooms with or without the novel collector in summer, the results show that when in summer, the novel solar system is available for serving hot water, and it does not have the summer overheating problem, and can even improve the thermal environment of its building slightly.

关 键 词:太阳能集热器 建筑一体化 制冷负荷 双功能 夏季 建筑热环境 耦合模型 循环水工程 

分 类 号:TU832[建筑科学—供热、供燃气、通风及空调工程] TK513[动力工程及工程热物理—热能工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象