某600MW超临界锅炉结渣原因分析及解决方法  被引量:2

Cause Analysis on Slagging of a 600 MW Supercritical Boiler and Solutions Thereof

在线阅读下载全文

作  者:张营帅[1] 任利明[1] 李有信[1] 贾天翔 

机构地区:[1]河南电力试验研究院,河南郑州450052 [2]沈阳伊莱瑞克电力设计院有限公司分公司,河南郑州450007

出  处:《锅炉技术》2010年第6期42-43,50,共3页Boiler Technology

摘  要:某600MW超临界锅炉运行期间结渣现象频繁,冷态试验发现三次风气流在调节范围内贴壁严重,电厂对旋流燃烧器结构进行了改造,增加了三次风外侧扩锥,使三次风气流贴壁现象彻底消除,调节三次风门可以改变三次风的旋流强度,煤粉燃烧状况得以改善,进而避免了锅炉结渣现象,提高了机组运行的安全性。A 600 MW supercritical boiler slags frequently in operation. Terriary air flow sticks to the wall in ajustable range in cold test, then the plant retrofits for swirling burners. By adding a bluff cone outside terriary air, the condition of terriary air flow sticking to the wall disappears, and the swirling intensity of terriary air changes through adjusting terriary air register. Thus, with the improvement of pulverized coal combustion condition, the boiler slagging phenomenon disappears and the safety of unit operation is enhanced.

关 键 词:结渣 燃烧器 三次风 旋流强度 

分 类 号:TK227.1[动力工程及工程热物理—动力机械及工程]

 